Acan, S orcid iconORCID: 0009-0007-1223-7178, Valenzuela‐Pascual, C, Corponi, F, Li, BM, Hidalgo‐Mazzei, D, Thijssen, D orcid iconORCID: 0000-0002-7707-5567, Vos, G, Bogaerts, S, Hermans, E, Baratchi, M, Dresler, M and De Looff, P (2026) Standardized synchronization and validation pipeline for physiological biomarkers across multiple devices. Behavior Research Methods, 58 (8). ISSN 1554-351X

[thumbnail of Standardized synchronization and validation pipeline for physiological biomarkers across multiple devices.pdf]
Preview
Text
Standardized synchronization and validation pipeline for physiological biomarkers across multiple devices.pdf - Published Version
Available under License Creative Commons Attribution.

Download (1MB) | Preview

Abstract

Wearable devices enable continuous monitoring of physiological signals in real‐world settings, yet a standardized approach for synchronizing signals across devices remains lacking. We present a generalizable, user‐friendly pipeline that enables synchronization of any two devices capturing the same physiological signals, without requiring coding expertise. The pipeline performs resampling, dynamic time warping alignment, amplitude correction via wavelet transforms, and signal standardization, followed by agreement analyses at both waveform and feature levels. To demonstrate its validity, we applied the pipeline to a case study comparing two research‐grade devices, the Empatica E4 and the EmbracePlus, using up to 48 h of concurrent recordings from 31 participants. We compared signal‐level agreement across waveform similarity, amplitude distribution, spectral content, and extracted features between the two research‐grade devices to determine their interchangeability for longitudinal and multi‐site studies. Specifically, we aimed to determine how well these devices agree at the signal level and to identify which physiological signals are most robust to device‐specific variability. Four signals were examined (blood volume pulse, electrodermal activity, accelerometry, and temperature) using NeuroKit2 and FLIRT. We computed Pearson and concordance correlation coefficients, Bland–Altman bias and limits of agreement, root mean squared error (RMSE), KL divergence, spectral coherence, mutual information, and feature‐level correlations using NeuroKit2 and FLIRT. Results showed near‐perfect agreement for BVP (concordance correlation coefficient (CCC) ≈ 1.0; coherence ≤ 0.98) and phasic EDA features (CCC 0.85–0.99), whereas tonic EDA, temperature, and accelerometry exhibited systematic amplitude biases (EmbracePlus lower) and axis‐dependent variability (Z‐axis CCC = 0.85; Y‐axis = 0.19). Relative signal dynamics were preserved across devices despite differences in absolute levels. These findings support integration of BVP, EDA, and TEMP data across E4 and EmbracePlus with proper preprocessing, while highlighting calibration needs for movement signals.

Item Type: Article
Uncontrolled Keywords: Synchronization; Statistical analysis; Empatica E4; EmbracePlus; Wearables; Alignment; Cross-platform interoperability; Humans; Monitoring, Physiologic; Reproducibility of Results; Galvanic Skin Response; Signal Processing, Computer-Assisted; Accelerometry; Biomarkers; Wearable Electronic Devices; Alignment; Cross-platform interoperability; EmbracePlus; Empatica E4; Statistical analysis; Synchronization; Wearables; Humans; Biomarkers; Wearable Electronic Devices; Monitoring, Physiologic; Signal Processing, Computer-Assisted; Accelerometry; Reproducibility of Results; Galvanic Skin Response; 5202 Biological Psychology; 5204 Cognitive and Computational Psychology; 49 Mathematical Sciences; 4905 Statistics; 52 Psychology; Clinical Research; Bioengineering; Humans; Biomarkers; Wearable Electronic Devices; Monitoring, Physiologic; Signal Processing, Computer-Assisted; Accelerometry; Reproducibility of Results; Galvanic Skin Response; 0801 Artificial Intelligence and Image Processing; 1701 Psychology; 1702 Cognitive Sciences; Experimental Psychology; 4905 Statistics; 5202 Biological psychology; 5204 Cognitive and computational psychology
Subjects: Q Science > QP Physiology
R Medicine > RC Internal medicine > RC1200 Sports Medicine
T Technology > T Technology (General)
Divisions: Sport and Exercise Sciences
Publisher: Springer
Date of acceptance: 8 June 2026
Date of first compliant Open Access: 20 August 2026
Date Deposited: 20 Aug 2026 13:36
Last Modified: 20 Aug 2026 13:36
DOI or ID number: 10.3758/s13428-026-03097-8
URI: https://researchonline.ljmu.ac.uk/id/eprint/29171
View Item View Item