Che, HS, Hew, W-P, Rahim, NA, Duran, MJ, Levi, E and Jones, M (2014) Postfault operation of an asymmetrical six-phase induction machine with single and two isolated neutral points. IEEE Transactions on Power Electronics, 29 (10). pp. 1131-1138. ISSN 0885-8993
There is a more recent version of this item available. |
|
Text
IEEETPE2014-HangSengChe.pdf Download (795kB) | Preview |
Abstract
The paper presents a study of postfault control for an asymmetrical six-phase induction machine with single and two isolated neutral points, during single open-phase fault. Postfault control is based on the normal decoupling (Clarke) transformation, so that reconfiguration of the controller is minimized. Effect of the single open-phase fault on the machine equations under this control structure is discussed. Different modes of postfault operation are analyzed and are further compared in terms of the achievable torque and stator winding losses. Validity of the analysis is verified using experimental results obtained from a six-phase induction motor drive prototype. © 1986-2012 IEEE.
Item Type: | Article |
---|---|
Subjects: | T Technology > TK Electrical engineering. Electronics. Nuclear engineering |
Divisions: | Electronics and Electrical Engineering (merged with Engineering 10 Aug 20) |