Che, HS, Duran, MJ, Levi, E, Jones, M, Hew, W-P and Abd Rahim, N (2013) Postfault Operation of an Asymmetrical Six-Phase Induction Machine With Single and Two Isolated Neutral Points. IEEE Transactions on Power Electronics, 29 (10). pp. 5406-5416. ISSN 0885-8993
This is the latest version of this item.
|
Text
IEEETPE2014-HangSengChe.pdf Download (795kB) | Preview |
Abstract
The paper presents a study of postfault control for an asymmetrical six-phase induction machine with single and two isolated neutral points, during single open-phase fault. Postfault control is based on the normal decoupling (Clarke) transformation, so that reconfiguration of the controller is minimized. Effect of the single open-phase fault on the machine equations under this control structure is discussed. Different modes of postfault operation are analyzed and are further compared in terms of the achievable torque and stator winding losses. Validity of the analysis is verified using experimental results obtained from a six-phase induction motor drive prototype.
Item Type: | Article |
---|---|
Additional Information: | (c) 2014 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other users, including reprinting/ republishing this material for advertising or promotional purposes, creating new collective works for resale or redistribution to servers or lists, or reuse of any copyrighted components of this work in other works |
Uncontrolled Keywords: | 0906 Electrical And Electronic Engineering |
Subjects: | T Technology > TK Electrical engineering. Electronics. Nuclear engineering |
Divisions: | Electronics and Electrical Engineering (merged with Engineering 10 Aug 20) |
Publisher: | IEEE |
Related URLs: | |
Date Deposited: | 13 Nov 2015 14:47 |
Last Modified: | 04 Sep 2021 14:08 |
DOI or ID number: | 10.1109/TPEL.2013.2293195 |
URI: | https://researchonline.ljmu.ac.uk/id/eprint/1716 |
Available Versions of this Item
-
Postfault operation of an asymmetrical six-phase induction machine with single and two isolated neutral points. (deposited 13 Aug 2014 08:16)
- Postfault Operation of an Asymmetrical Six-Phase Induction Machine With Single and Two Isolated Neutral Points. (deposited 13 Nov 2015 14:47) [Currently Displayed]