Facial reconstruction

Search LJMU Research Online

Browse Repository | Browse E-Theses

A novel miniature in-line load-cell to measure in-situ tensile forces in the tibialis anterior tendon of rats.

Schmoll, M, Unger, E, Bijak, M, Stoiber, M, Lanmüller, H and Jarvis, JC (2017) A novel miniature in-line load-cell to measure in-situ tensile forces in the tibialis anterior tendon of rats. PLoS One, 12 (9). ISSN 1932-6203

[img]
Preview
Text
M:\My Documents\Documents JMU\papers 2017\load cell plos\published version.pdf - Published Version
Available under License Creative Commons Attribution.

Download (5MB) | Preview

Abstract

Direct measurements of muscular forces usually require a substantial rearrangement of the biomechanical system. To circumvent this problem, various indirect techniques have been used in the past. We introduce a novel direct method, using a lightweight (~0.5 g) miniature (3 x 3 x 7 mm) in-line load-cell to measure tension in the tibialis anterior tendon of rats. A linear motor was used to produce force-profiles to assess linearity, step-response, hysteresis and frequency behavior under controlled conditions. Sensor responses to a series of rectangular force-pulses correlated linearly (R2 = 0.999) within the range of 0-20 N. The maximal relative error at full scale (20 N) was 0.07% of the average measured signal. The standard deviation of the mean response to repeated 20 N force pulses was ± 0.04% of the mean response. The step-response of the load-cell showed the behavior of a PD2T2-element in control-engineering terminology. The maximal hysteretic error was 5.4% of the full-scale signal. Sinusoidal signals were attenuated maximally (-4 dB) at 200 Hz, within a measured range of 0.01-200 Hz. When measuring muscular forces this should be of minor concern as the fusion-frequency of muscles is generally much lower. The newly developed load-cell measured tensile forces of up to 20 N, without inelastic deformation of the sensor. It qualifies for various applications in which it is of interest directly to measure forces within a particular tendon causing only minimal disturbance to the biomechanical system.

Item Type: Article
Uncontrolled Keywords: MD Multidisciplinary
Subjects: R Medicine > RC Internal medicine > RC1200 Sports Medicine
Divisions: Sport & Exercise Sciences
Publisher: Public Library of Science
Related URLs:
Date Deposited: 04 Oct 2017 11:11
Last Modified: 04 Sep 2021 11:09
DOI or ID number: 10.1371/journal.pone.0185209
URI: https://researchonline.ljmu.ac.uk/id/eprint/7273
View Item View Item