Facial reconstruction

Search LJMU Research Online

Browse Repository | Browse E-Theses

Development, Optimisation, Validation and Inter-Laboratory Verification of a Reversed Phase HPLC Method for Quantification of Human Recombinant Insulin

Iyire, A, Russell, C, Dennison, T, Rajoli, R, Saleem, IY, Rahman, A and Mohammed, A (2018) Development, Optimisation, Validation and Inter-Laboratory Verification of a Reversed Phase HPLC Method for Quantification of Human Recombinant Insulin. Journal of Advances in Biotechnology, 7 (1). pp. 984-998. ISSN 2348-6201

[img]
Preview
Text
Development, optimisation, validation and inter-laboratory verification of a reversed phase HPLC method for quantification of human recombinant insulin.pdf - Accepted Version
Available under License Creative Commons Attribution.

Download (1MB) | Preview

Abstract

HPLC methods for insulin in official monographs require extended runtimes and elevated temperatures. Inter-laboratory reproducibility of HPLC methods obtained from published literature is an on-going challenge, moreso for peptides. This paper serves as a step-by step guide to troubleshoot and establish a validated HPLC method for insulin at room temperature using simple UV detectors with minimal run times. A modified gradient reversed-phase HPLC was developed for the quantification of recombinant human insulin with UV detection at room temperature. An octadecylsilica column was used as the stationary phase while the mobile phase consisted of solution A: 1mmol sodium sulphate and 0.2% triethylamine in water and solution B: acetonitrile. The developed method was then validated using International Conference on Harmonisation (ICH) guidelines. The calibration curve was linear over a concentration range of 10-1000 μg/mL with correlation coefficient of 0.9993, with average recovery percent of 100.89 ± 1.4% and RSD recovery of 0.01. Insulin retention time was 3.84 ± 0.08 mins, while LOD and LOQ were estimated at 0.63 and 2.0 μg/mL respectively. The developed method conformed to the validation criteria of the ICH guidelines in our laboratories and other independent operator laboratories, and can serve as a rapid and effective method for quantifying insulin from any sample at room temperature using simple detectors.

Item Type: Article
Subjects: R Medicine > RM Therapeutics. Pharmacology
Divisions: Pharmacy & Biomolecular Sciences
Publisher: CIRWORLD
Date Deposited: 10 Jul 2018 09:30
Last Modified: 04 Sep 2021 02:35
DOI or ID number: 10.24297/jbt.v7i1.7192
URI: https://researchonline.ljmu.ac.uk/id/eprint/8935
View Item View Item